Key takeaways

  • Mining sites already collect huge amounts of condition monitoring data, but when events, alerts, and alarms all get treated the same way, the important warnings often disappear into the noise.
  • Better alarm management improves operational efficiency by cutting down nuisance notifications and helping teams focus on the problems that actually need attention.
  • Predictive maintenance only improves asset performance when alerts are trusted, understood, and turned into prioritized maintenance action instead of becoming another ignored dashboard notification.
  • The best condition monitoring programs help teams schedule maintenance before failures escalate, reducing unplanned downtime, repair costs, and the flow-on damage that developing faults can create.

Why more visibility hasn’t reduced unplanned downtime

The mining industry has more condition monitoring data than it has ever had before, but failures are still happening, and frequently.

Equipment failures like seized gearboxes, failed bearings, and destroyed haul truck engines are often treated as sudden events, right up until the investigation reveals the warning signs had already been sitting in the condition monitoring data for weeks or months beforehand.

In our experience working across mining operations, from mobile fleets through to fixed plants, the problem is rarely a lack of data, sensors, or monitoring systems. Most sites already have more condition information than their teams can realistically process, and that overload is part of the issue.

The real challenge is deciding what matters, what does not, and what actually requires action. Oil analysis, telemetry, inspections, operator reports, and maintenance history are often spread across disconnected systems, making it difficult to see developing failure modes clearly or prioritize risk across a mixed fleet. 

Events, alarms, and alerts are not the same thing

The mining industry uses these three words as though they were interchangeable. They are not, and the consequences of treating them that way are felt every day on every site. The definitions below come from ANSI/ISA-18.2, the international standard for alarm management, adapted to a maintenance context.

1. An event is a fact

It is the recorded observation that some monitored parameter has crossed some defined value. For example, a vibration channel exceeded 7 mm/s or an oil sample returned iron above 50 ppm. It’s as simple as the event happened, and it was logged. An event, by itself, is not a reason to do anything.

2. An alarm is an event that demands immediate attention from an operator

It indicates an abnormal condition that requires a timely response, right now, to prevent an undesirable outcome. The operator is expected to do something. If no one is expected to do anything, it is not an alarm.

3. An alert is something else entirely

An alert is a notification of an abnormal condition that requires assessment or action by someone other than the operator, typically a maintenance technician, reliability engineer, or asset health analyst. Alerts don’t require a response within the next 60 seconds. They demand a considered response in the next hours, days, or weeks.

This is the kind of pressure modern operations face every day. It’s why condition monitoring matters, why predictive maintenance exists, and why we do what we do.

Most of what the mining industry calls an “alarm” in condition monitoring is, by the standard’s own definition, an alert. And most of what it calls an “alert” is actually an event. This sloppy language is the root of alarm fatigue.

If every event becomes an alarm and every alarm demands attention, people eventually stop reacting the way they should. The important signals get lost in the flood of notifications, and trust in the system starts to disappear.

The real root causes of alarm fatigue

People like to point to “alert fatigue” and “reactive culture” as the cause. They are not causes. They are warning signs of deeper problems most organisations would rather avoid discussing directly.

Nuisance alarms have destroyed trust

When thresholds repeatedly trigger on ordinary operating variation, people learn to tune them out. It’s not laziness or negligence, but a response shaped by experience, where alarms have consistently failed to signal anything worth acting on.

ISA-18.2 defines “alarm flood” as more than ten alarms in a ten-minute window, a state in which effective response is no longer possible. We routinely see mining monitoring systems generating that volume, and then everyone wonders why nothing gets actioned.

There is no consequence for ignoring an alarm

It is difficult to admit, but in many maintenance organizations there is no real consequence for ignoring an alarm. The notification clears, operations continue, and when the bearing eventually fails weeks later, the original warning has long been forgotten. Without feedback, accountability disappears, and behavior stays exactly the same.

These two causes feed each other. Nuisance alarms make people stop trusting the system. Lack of consequences makes ignoring untrustworthy alarms the rational choice.

What good alarm design actually looks like

Beneath every effective alarm management strategy is a process known as alarm rationalization. It involves formally reviewing each potential alarm to determine if it’s necessary, what condition it’s signalling, who should respond, and what response is required.

The difference between a rationalized alarm system and an unrationalized one usually comes down to three things.

It is grounded in the actual machine, not in generic limits

Most condition monitoring alarms used across mining today are still built around generic industry thresholds, including limits published by oil laboratories, vibration severity tables pulled from textbooks, or temperature ranges lifted from OEM specification sheets. Those benchmarks are useful as a starting point, but they become dangerous when treated as final answers rather than baselines.

Take the same haul truck engine operating in two completely different environments, one working through Pilbara dust and extreme heat, the other running through a Canadian winter. The operating patterns, contamination exposure, thermal behavior, load conditions, and wear characteristics will look nothing alike, yet many systems still attempt to apply the same alarm limits to both.

Effective alarm management comes from calibrating alarms against the operational history, environmental conditions, duty cycle, and behavioral patterns of the individual asset being monitored.

It uses alarm conditioning

A single event crossing a threshold is rarely a reason to act, but a pattern of events is.

ISA-18.2 refers to this as “alarm conditioning”, using tools like delay timers (“the temperature must stay above 80°C for more than three minutes”) or n-out-of-m logic (“the threshold must be crossed five times within an hour”) to filter out normal operating noise before it ever reaches a person.

Most mining condition monitoring systems still trigger on the first threshold crossing, then trigger again minutes later, and again after that, flooding operators with repetitive notifications that carry very little context or urgency.

It is triaged by a human who understands what the data means

Raw alerts are findings, not recommendations. Someone with domain expertise has to review the finding, understand the failure mode it implies, and translate it into a clear recommendation: do this, by this date, because of this risk.

This is the difference between a system that generates work and a system that generates the right work.

How DINGO handles it differently

Most predictive maintenance solutions stop at “we sent you an alert.” Ours doesn’t, and the difference is structural.

We design alarms against the asset’s actual history, not against generic limits

When TRAKKA is deployed on a haul truck, a mill, a pump, or a critical drive, the alarm settings reflect that asset’s operating history, that site’s context, and the failure modes that matter for that piece of equipment. Generic limits tell you what should happen in theory, but ours tell you what is actually happening in your pit or processing plant.

We use alarm conditioning by default

A single threshold crossing is rarely the basis for an action in our system. Rather than reacting to isolated threshold crossings, our process looks at patterns, persistence, recurrence, rate of change, and asset context before findings are escalated to customers.  The result is that when our customers see a notification from us, it has already gone through a layer of filtering that most systems do not apply.

Our Condition Intelligence analysts review critical findings and actionable alerts, validate them against the likely failure mode 

Our Condition Intelligence analysts review alerts, validate them against the failure mode they imply, assess severity and confidence, and translate them into a specific recommendation with a specific action. Instead of drowning in raw dashboard data, customers receive clear, prioritized guidance.

This is what we mean when we say predictive maintenance has to lead to planned work. The link between data and work order is engineered by humans who understand what they’re looking at, and it starts with understanding the difference between predictive and preventive maintenance.

What this approach actually prevents

The risks that a well-designed alarm and alert program prevents fall into four categories, and they are the categories that matter to the people who sign maintenance budgets.

1. Catastrophic failure and the cost of unplanned replacement

An asset that fails in service costs several times more to deal with than the same repair done on your terms. With major rotating equipment like engines, gearboxes, and drives, a catastrophic failure can run into seven figures. Not because the part is more expensive, but because of the collateral damage, emergency freight, contract labor, and procurement at any price that come with it.

The whole point of catching a failure mode early is to convert that unplanned spend into a planned, budgeted, lower-cost intervention.

2. Lost production

In mining, the cost of downtime on a critical asset is rarely measured in repair dollars. It is measured in tonnes, ounces, or pounds of product not produced. A single day of unplanned downtime can dwarf the repair cost by an order of magnitude or more. Alarm management that surfaces real problems early and filters out the noise that distracts from them directly protects production.

3. Safety exposure

Equipment that fails unexpectedly poses a safety risk. A seized bearing, a ruptured hydraulic line, or a fractured structural component is not merely a maintenance issue; they are potential incidents waiting to occur. Effective alarm management that detects failure modes early can prevent these safety events from happening.

4. Poor asset performance and health

Assets that are run with undetected developing faults degrade faster than they should, and often by the time the failure is obvious, the secondary damage has already reduced the lifespan of other components that were not the initial problem. Identifying and addressing the root cause early helps prevent downstream damage.

Case study: the diesel engine that was almost lost

A few years ago, one of our customer sites had been receiving routine oil analysis reports from their lab indicating elevated silicon and iron levels in a haul truck diesel engine, which is a common sign of dust ingress through a compromised air intake system.

The oil reports had been flagging elevated contamination levels for months, but the limits used were generic industry benchmarks that were frequently triggered. After seeing countless similar alerts go nowhere, the site’s reliability team had understandably stopped treating them as urgent.

Looking at the same reports through TRAKKA, our Condition Intelligence team identified something the generic thresholds had missed. The contamination trend matched a developing abrasive wear issue that was progressing toward major engine damage.

At that rate, silicon ingress was damaging the engine internals, leading to liner scoring, accelerated ring wear, and, eventually, catastrophic engine failure. The kind that sidelines a haul truck for weeks and creates massive costs in repairs, lost production, and replacement parts. We issued an alert recommending an immediate inspection of the air intake system, remediation of the ingress point, and an oil change within a defined timeframe.

The site followed the recommendation and identified a failed air filter seal as the source of the dust ingress. The seal was replaced during planned maintenance, the oil was changed, and the engine stayed in service without any unplanned downtime.

What to demand from any predictive maintenance program

If you are evaluating a predictive maintenance system, whether that’s DINGO‘s or anyone else’s, there are three questions you should ask, and the quality of the answers will tell you everything.

  1. How are your alarm thresholds set, and are they calibrated to the specific asset and operating context, or are they generic? If the answer is “we use industry-standard limits,” you are buying a nuisance alarm generator.
  2. Do you apply alarm conditioning, and if so, what kind? If the vendor doesn’t know what alarm conditioning is, they are not doing it.
  3. Who triages the alerts before they reach my team, and what are their qualifications? Software can help surface patterns faster, but without operational context and expert interpretation, most organizations still struggle to convert findings into the right maintenance actions. 

Your predictive maintenance software should make problems easier to spot, not harder

The mining industry doesn’t need more raw data nearly as badly as it needs better interpretation and better filtering. Until the industry improves how it designs and triages alarms, more sensors and more dashboards will only make the noise louder.

Predictive maintenance software creates value when alerts lead to action, not just more notifications. That depends on good alarm design, proper conditioning, and people who can interpret the signal and turn it into planned work.

If you are wondering whether your current condition monitoring program is generating noise or generating decisions, the answer is probably visible in one number: what percentage of the alerts you received last quarter resulted in planned work?

If you don’t know, that is the first finding. If you do know, and the number is low, that is the second.

We’d be happy to help you change both numbers.

If your team is overwhelmed by condition monitoring noise, struggling with alarm fatigue, or finding that too few alerts translate into planned work, we’d be happy to show you how other mining operations are approaching the problem